LV Dummy page
Low Voltage Switchgear for Critical Power Applications
Schneider Electric offers a wide variety of low voltage Square D® power distribution products. From our QED-2 Powerstyle® switchboards using group-mounted I-Line® construction to our QED-6 compartmentalized switchboards. Schneider Electric provides a complete UL offering. Power-Zone® 4 Switchgear is built to strict ANSI standards and features the industry preferred Masterpact® NW and NT circuit breakers. These products and components are the preferred choice for many end users, consultants and contractors. They are used by many of the leading specialty OEMs sub-systems such as paralleling switchgear and UPS equipment.
Power-Zone 4® Low Voltage Switchgear with Masterpact® NW and NT Circuit Breakers
The versatility of Square D low voltage switchgear makes it the perfect protection for a wide range of switching and control applications. With Power-Zone 4 (PZ4), Square D offers the next generation of proven, reliable and durable low voltage switchgear. We developed it with your values in mind to improve your electrical system running time and efficiency. >more...
|
|
PZ4 has the following benefits:
In addition, Power-Zone 4 switchgear with Masterpact NT/NW circuit breakers feature:
Technical Data | Brochures | Online Catalog | Specifications | Power Distribution Products |
-
Available up to 5000A bus rating
-
Micrologic® trip units with power monitoring, control and communications
-
Optional PLC based auto transfer schemes
-
Optional Transparent ReadyTM communications utilizing PowerLogic®
-
Optional Surgelogic® TVSS
-
Differential ground fault option for 4W systems with multiple sources
-
Arc flash application options
-
Arc flash limiting feeder breakers up to 2000A reduce arc incident energy on downstream equipment such as UPSs and PDPs
-
Thru-the-door breaker operation allows unit to be operated/racked while door is closed; this reduces NFPA 70E PPE category by one level
-
Rear-hinged doors allow easy access to cables; this reduces NFPA 70E 2004 PPE category by one level
-
Benefits of using Power-Zone® 4 in data center applications:
-
Drawout construction is required for quick circuit breaker change-out
-
Transfer system requirements call for circuit breakers to close within 5-cycles and stored energy circuit breakers are required for reliability
-
Front access to control wires is desired for ease of installation, maintenance and upgrade
-
Circuit breaker compartmentalization is required for system integrity
-
Segregation of circuit breaker compartments, from bus and cable compartments, is required for equipment
Switchboards - Rear Connected QED-6 with Masterpact Circuit Breakers and PowerLogic Monitoring
Rear connected switchboards offer many of the same benefits of ANSI rated switchgear listed above. Short times withstand ratings on the breakers, structures and as well as high short circuit interrupting ratings. Lower equipment cost, 100% rated drawout breakers (breaker frame sizes to 250A to 5000A) and maintainability for extended life are reasons this product is used in these facilities.
![]() |
Data Center Application:
QED-6 switchboard structures offer many of the same benefits as Power-Zone 4 switchgear. Some of these feature differences are:
|
Spotlight: View the Masterpact NT Series Circuit Breaker webcast - this breaker is a fully tested, full-feature power circuit breaker in the smallest footprint available on the market today. Run length is 7.5 minutes. |
Learn More: Download the Power Zone 4 BrochureLearn More about our MCC product family Learn More about the Power Zone 4 LV Switchgear |